Why is my dark or flat not being applied?

Calibration assignment reports exactly what it could not do, next to the frames it affects. This page works through each message and what fixes it. For how matching works in the first place, see how calibration is assigned.

Beside this message is the criteria line it searched on, for example:

QHY268M · gain 56 · no readout mode · 1×1 · 720 s @ 0 °C

Read it as a list of what a master needs to carry. Every term is a field the master you need has to match, in full, including any field that reads as absent. Check whether a candidate master actually has those fields set. An imported master, one integrated outside EigenFrame, often lost gain, offset, readout mode, set temperature and exposure time in the integration process, so it can no longer match a light on any of them. See will EigenFrame read my data for what an imported master keeps and loses, and what to assert by hand when it isn’t enough.

Screenshot: Session page, an unresolved dark row showing the criteria it searched on.

A dark carries two extra requirements beyond the shared camera signature: the light’s exposure time has to match exactly, and its set temperature has to fall within the rig’s tolerance, 7 °C by default and adjustable per rig on the Equipment page. Among the darks inside that tolerance the nearest set temperature is chosen; nothing outside it is ever picked automatically.

Some rigs are legitimately shot without darks at all, a cooled sensor with negligible amp glow calibrated on bias alone. For that case the unresolved row offers Darks not used on this rig. Turning it on stops an unassigned dark on that rig from being reported as a gap; a dark that is actually assigned still applies normally, the setting only silences the warning.

A missing dark is shown as advisory, not a hard gap, whenever the light’s bias resolved on its own, since the bias still corrects the frame. The real gap is when both the bias and the dark come up unresolved for the same light.

A criteria entry reads “no readout mode” (or similarly missing)

Section titled “A criteria entry reads “no readout mode” (or similarly missing)”

When a criteria entry names an absent value like “no readout mode” or “no gain”, the light itself is missing that field in its own header, not the candidate masters. Absence is compared like any other value, so a light missing a field only matches a master that is equally missing it; it never falls back to matching anything.

The fix is one of two things: find or build a master that is missing the same field, or remove that field from the rig’s match signature on the Equipment page so it stops being compared at all. See how calibration is assigned for the underlying rule.

This means EigenFrame searched the rig’s flats for this filter and found none inside the light’s epoch. The row links straight to building one for that filter and date. If a flat does exist nearby but isn’t showing up, check which side of an epoch boundary it falls on, covered next.

A flat message that calls out an optical-train change means a flat exists near the light in time, but the two sit on opposite sides of a marked boundary, so it is never assigned automatically no matter how close the dates are. See how long is a flat good for for what an epoch is and how a boundary gets marked.

Two ways out: shoot fresh flats on the current side of the boundary and build a master from those, or deliberately pick the cross-epoch flat yourself from the viewer’s Calibration tab, knowing it will be treated as suspect on that frame.

A flat is assigned, but its statistics are still being prepared

Section titled “A flat is assigned, but its statistics are still being prepared”

A newly built or newly assigned flat needs its pixel statistics computed before it can actually correct a frame. Until that finishes it shows as still preparing rather than ready, and it does not calibrate yet. No action is needed, it becomes effective on its own once preparation completes; reopening the frame afterward shows it corrected.

The assigned master was rejected or is missing

Section titled “The assigned master was rejected or is missing”

This is the ✗ state: the master a frame points at has since been rejected, or the record itself is gone. Use Autodetect calibration on the session page or the target’s filter tab. It re-points only the frames whose assignment has actually gone bad, rejected, missing, or a flat that has become cross-epoch, and leaves every other assignment untouched.

This is the blunt instrument. It discards every current bias, dark and flat assignment in scope and re-derives them all from the best available masters, including assignments you set by hand and deliberate “none” choices. It confirms first with the frame count and scope, and it cannot be undone. Reach for Autodetect first; use Reset & reassign only when you want to start a scope’s calibration over from nothing.

The viewer’s Calibration tab always shows the current bias, dark and flat for the open frame, ranked candidates for each, and the same criteria line when nothing matches. It’s the place to confirm what’s actually assigned to a single frame and to override it without touching anything else in scope.