Skip to content

What does every setting do, and what is its default?

One row per setting, grouped by where it lives. Each links to the page that explains it in full; this page exists so a setting is never more than one lookup away.

Per folder, in Manage Library. See library folders.

SettingControlsDefault
Include subdirectoriesWhether the folder walks into its subfoldersOn
Intake scopeWhich detected categories (Frames, Masters) and subtypes (Lights, Flats, Darks, Bias) the folder contributesEverything
Override (type)Labels arriving files as a chosen type regardless of their headerNone (uses the detected type)
Equipment groupAssigns arriving lights and flats to a chosen rig instead of auto-discovering oneAuto-discover
Import rulesAn ordered list of path patterns that exclude files or force a typeNone. See import rules
Exclude patternsFull-path glob patterns skipped on scanNone

From the Equipment page rig editor. This list matches rigs and equipment groups exactly; that page is the fuller explanation of each one.

Screenshot: The Equipment page rig editor scrolled to the alignment tolerances.

SettingControlsDefault
RulesAttribute and value or range a frame must match to join this rigNone (a rig with no rules matches nothing)
Calibration match fields, biasWhich header fields a bias master must match onInstrument, gain, offset, readout, X binning, Y binning
Calibration match fields, darkWhich header fields a dark master must match onThe bias default plus exposure and set temp
Dark framesWhether an unassigned dark is flagged as missing calibrationRequired
Flat framesWhether an unassigned flat is flagged as missing calibrationRequired
Dark set-temp toleranceHow close a dark’s set temp must be to a light’s for automatic selection7°C
Star detectionCandidate bounds, acceptance settings, and quality thresholds for star detection. See star detection and frame qualityShipped defaults; quality thresholds blank means flagging is off
Alignment tolerancesRotation and scale a fit may land in and still be plausible, and whether a 180° flip is allowed. See when frames will not alignRotation ± 5.0°, Scale ± about 2%, 180° flip allowed
Output pedestal (DN)Baseline added to a stacked master so the stored image stays positive250
Stack output pathsPer-frame-type filename template override for this rigBlank (inherits the library default)
Integration presetsSaved stacking settings for this rig, reusable across its targets. See stack presetsNone until you save one

From Performance Settings in the gear menu. Full guidance, including how to tune each one, is on performance and cache; this is the default for each knob.

SettingDefault
Read Concurrency3
Scan Concurrency0 (automatic: 4 on a local drive, 16 on a network share)
Compute ConcurrencyCPU count, capped at 16
Stack jobs (concurrent)4
Stacking reserved workers (under contention)4
Viewer reserved workers (under contention)8
Alignment evaluate concurrencyCPU count minus 2, never below 2, capped at Compute Concurrency
In-Flight Memory Budget4 GB
Cache Size Cap8 GB
Stacking Tile Cache4 GB
Stack Memory Budget0 (automatic: half the machine’s RAM, floored at 4 GB)
Cache Eviction Headroom1 GB
Drive Free-Space Reserve2 GB
Drive Eviction Target8 GB
Stalled-read timeout5 seconds
Cache LocationEmpty (uses %APPDATA%/EigenFrame/tiles-cache)

From Stack Outputs in the gear menu, one template per frame type, plus a per-rig override on the Equipment page. See where stacks are saved.

TemplateDefault
BiasEigenFrame/Masters/Bias/{SessionDate}.MasterBias.Gain.{Gain}.Offset.{Offset}{.ReadoutMode?}.{NCombine}x{ExposureTime}s
DarkEigenFrame/Masters/Dark/{SessionDate}.MasterDark.Gain.{Gain}.Offset.{Offset}{.SetTemp?}.{NCombine}x{ExposureTime}s
FlatEigenFrame/Masters/Flat/{SessionDate}.MasterFlat{.Filter?}.Gain.{Gain}.Offset.{Offset}.{NCombine}x{ExposureTime}s
LightEigenFrame/Integrations/{Object}/{Object}_{Filter}_{SessionDate}

A per-rig override is blank by default, which inherits the template above.

The Send diagnostics toggle and its connection string live at the bottom of Performance Settings. See diagnostics and telemetry.

SettingControlsDefault
Send diagnosticsWhether operational events leave your machine at allOff
Connection StringWhere diagnostics are sent when the toggle is onBlank (sends to the EigenFrame team’s endpoint)